We use cookies to ensure you get the best experience on our website. For more information on how we use cookies, please see our cookie policy.
By clicking "Accept", you agree to our use of cookies.
Learn more.

Technical documents and specifications for this product.
Siemens LCS 100
SITRANS LCS100 is a point level switch designed to detect point level in liquids, solids, slurries, foam, and for interface detection. Its compact design makes it ideal for use in confined spaces and offers plastic or stainless steel process connections along with flexible rod and cable probe extensions. SITRANS LCS100 is utilised for overflow, high, low, and demand applications, as well as for pump protection. It operates effectively in all types of vessels, pipes, and silos across a broad range of industries, including food, pharmaceuticals, chemical, petrochemical, water, and machine building.
SITRANS LCS100's flexible insertion length, starting at 92 mm (3.6 inch), and its versatility across various applications and within vessels or pipes, makes it a suitable choice for most point level applications. Its advanced design ensures accurate and repeatable switchpoint performance. The PPS (Polyphenylene sulphide) probe [optional PVDF (Polyvinylidene Fluoride)] and optional PEEK offer chemical resistance with an effective process operating temperature range from ‑40 to +125 °C (‑40 to +257 °F). The fully potted design ensures reliability in vibrating environments such as agitated tanks. When used with a SensGuard protection cover, the LCS100 is protected from shearing, impact, and abrasion in demanding primary processes.
The SITRANS LCS100 is available with either a stainless steel enclosure or a polyester enclosure, and offers stainless steel or PPS process connection options.
Key Applications: liquids, slurries, powders, granules, food and pharmaceuticals, chemicals, hazardous areas.
| Compact (7ML701 and 7ML700) | Extended (7ML702 and 7ML703) | |
|---|---|---|
| Mode of Operation - Measuring principle | Capacitive level detection | Capacitive level detection |
| Input - Measured variable | Change in picoFarad (pF) | Change in picoFarad (pF) |
| Output signal - Alarm output | 8/16 mA or 4 ... 20 mA, 2-wire loop or IO-Link, PNP, NPN | 8/16 mA or 4 ... 20 mA, 2-wire loop or IO-Link, PNP, NPN *IO-Link not available with Cable version |
| Switch output | 4-wire relay (general purpose) or transistor (intrinsically safe) | 4-wire relay (general purpose) or transistor (intrinsically safe) |
| Fail-safe mode | Min. or max. | Min. or max. |
| Accuracy - Repeatability | 2 mm (0.08 inch) | 2 mm (0.08 inch) |
| Rated operating conditions - Location | Indoor and outdoor | Indoor and outdoor |
| Ambient conditions - Ambient temperature | ‑40 ... +85 °C (‑40 ... +185 °F) | ‑40 ... +85 °C (‑40 ... +185 °F) |
| Ambient conditions - Storage temperature | ‑40 ... +80 °C (‑40 ... +176 °F) | ‑40 ... +80 °C (‑40 ... +176 °F) |
| Ambient conditions - Installation category | I | I |
| Ambient conditions - Pollution degree | 4 | 4 |
| Medium conditions - Relative dielectric constant εr | Min. 1.5 | Min. 1.5 |
| Medium conditions - Process temperature | ‑40 ... +125 °C (‑40 ... +257 °F), see temperature curve | |
| Medium conditions - Pressure (vessel) | ‑1 ... 25 bar (363 psi) – Stainless Process connection ‑1 ... 10 bar (146 psi) – PPS process connection |
‑1 ... 25 bar (363 psi) - Rod extensions ‑1 ... 10 bar (146 psi) - Cable extensions |
| Degree of protection - Enclosure Ø65 mm | Type 4X/IP68 | |
| Degree of protection - Enclosure Ø35 mm | Type 4X/IP68 | Not applicable |
| Cable inlet | ½" NPT or M20 x 1.5 | |
| Device version - Body (enclosure version) | Thermoplastic polyester | |
| Device version - Lid (enclosure version) | Transparent thermoplastic polycarbonate (PC) | |
| Device version - Enclosure Ø35 mm | 316L stainless steel | Not applicable |
| Device version - Sensor length (nominal) | 92 mm (3.6 inch) | 300 ... 4 000 mm (11.8 … 157 inch) - Rod version 400 ... 20 000 mm (15.7 ... 787 inch) - Cable version |
| Device version - Process connection material of probe/wetted parts | Connection: 316L stainless steel or PPS; Process seal: FKM (optional FFKM); Sensor: PEEK or PPS or PVDF |
Connection: 316L stainless steel or PPS; Process seal: FKM (optional FFKM); Sensor: PPS or PVDF Extension: Pipe 316L Cable: FEP jacketed |
| Device version - Connection (Enclosure 65 mm) | Terminal block, terminals 0.14 ... 1.5 mm2 (AWG 28 ... 16) or M12 x 1 according to IEC 61076-2-101, male, 4-pole, coding A-standard | |
| Device version - Connection (Enclosure 35 mm) | M12 x 1 according to IEC 61076-2-101, male, 4-pole, coding A-standard | Not applicable |
| Device version - Process connection | Thread: G ½", G ¾", G 1“, NPT ¾" Tri-clamp DN25 (1"), DN40 (1 1/2"), DN50 (2") DIN 32676 Type A (DIN 11851) and DIN 32676 Type C (ASME BPE 2009) Flange (screwed) DN 25, 40, 50; ASME 1", 1 ½”, 2" |
Thread: G ¾", G 1“, NPT ¾" Flange: DN 25, 40, 50; ASME 1", 1 ½”, 2" Adapters for G 1 ½", NPT 1 ¼", NPT 1 ½" |
| Power supply - Standard | 4-wire with relay supply: 9 ... 33 V DC, 0.7W including 10 % of EN 61010-1 2-wire with 8/16 or 4 ... 20 mA loop: 9 ... 33 V DC, 0.7W including 10 % of EN 61010-1 IO-Link / PNP / NPN 10 ... 30 V DC, incl. 10 % of EN 61010-1 |
|
| Power supply - Intrinsically Safe | 2-wire with 8/16 or 4 ... 20 mA loop: 10.8 ... 30 V DC, 0.7W incl. 10 % of EN 61010-1, intrinsically safe barrier required 4-wire with relay: 10.8 .... 30 V DC, 0.7W incl. 10 % of EN 61010-1, intrinsically safe barrier required |
|
| Certificates and approvals | General purpose: CE, UKCA, FM, CSA ATEX II 1G, 1/2G Ex ia IIC ATEX II 1D, 1/2D Ex ia IIIC IEC Ex ia IIC IEC Ex ia IIIC FM/CSA IS Class I, II, III, Div. 1, Groups A ... G Overfill protection: WHG (Germany) VLAREM |
|